Language and regionEnglish · AustraliaAU
Quick-reference table

One load.
19 batteries.

Every cell below uses rated capacity × 80% ÷ average load. It is a consistent planning comparison—not a measured runtime claim.

Capacities come from the documented manufacturer records in the Australian product profiles. Only records tied to an official Australian source carry an Australian-execution claim; every other model needs its own 230V/50Hz Type I verification, RCM evidence, responsible-supplier check and included-lead check before use. Runtime remains a calculation. No stock, price, warranty or affiliate status is asserted.

Calculate your exact load →
80% usable-energy comparison

Estimated hours by average load

Starting power must be checked separately. A runtime cell does not prove that a motor or appliance can start.

Average loadBLUETTIAC70768WhEcoFlowDELTA 3 Plus1,024WhBLUETTIAC1801,152WhEcoFlowDELTA 21,024WhDJIPower 10001,024WhAnker SOLIXC10001,056WhAnker SOLIXC1000 Gen 21,024WhJackeryExplorer 1000 v21,070WhAnker SOLIXC800768WhEcoFlowRIVER 3 Max Plus858WhBLUETTIElite 100 V21,024WhJackeryExplorer 2000 v22,042WhEcoFlowDELTA 2 Max2,048WhBLUETTIAC200L2,048WhJackeryExplorer 2000 Plus2,042.8WhAnker SOLIXF30003,072WhAnker SOLIXF38003,840WhJackeryExplorer 3000 v23,072WhEcoFlowDELTA Pro 34,096Wh
10Wsmall electronics61.4hours81.9hours92.2hours81.9hours81.9hours84.5hours81.9hours85.6hours61.4hours68.6hours81.9hours163.4hours163.8hours163.8hours163.4hours245.8hours307.2hours245.8hours327.7hours
25Wsmall electronics24.6hours32.8hours36.9hours32.8hours32.8hours33.8hours32.8hours34.2hours24.6hours27.5hours32.8hours65.3hours65.5hours65.5hours65.4hours98.3hours122.9hours98.3hours131.1hours
50Wmobile / work12.3hours16.4hours18.4hours16.4hours16.4hours16.9hours16.4hours17.1hours12.3hours13.7hours16.4hours32.7hours32.8hours32.8hours32.7hours49.2hours61.4hours49.2hours65.5hours
100Wmobile / work6.1hours8.2hours9.2hours8.2hours8.2hours8.4hours8.2hours8.6hours6.1hours6.9hours8.2hours16.3hours16.4hours16.4hours16.3hours24.6hours30.7hours24.6hours32.8hours
200Wmedium load3.1hours4.1hours4.6hours4.1hours4.1hours4.2hours4.1hours4.3hours3.1hours3.4hours4.1hours8.2hours8.2hours8.2hours8.2hours12.3hours15.4hours12.3hours16.4hours
500Wmedium load1.2hours1.6hours1.8hours1.6hours1.6hours1.7hours1.6hours1.7hours1.2hours1.4hours1.6hours3.3hours3.3hours3.3hours3.3hours4.9hours6.1hours4.9hours6.6hours
1000Whigh load0.6hours0.8hours0.9hours0.8hours0.8hours0.8hours0.8hours0.9hours0.6hours0.7hours0.8hours1.6hours1.6hours1.6hours1.6hours2.5hours3.1hours2.5hours3.3hours

Values round to one decimal. At very low draw, unbudgeted inverter or station overhead can shorten runtime substantially. Battery condition, temperature, power-saving behaviour and load variation also change real results.

How to use the chart

Bracket the load before trusting one number.

Example 01

50W load on 1,024Wh

1,024Wh × 80% ÷ 50W = about 16.4 hours. Add measured idle overhead to the load for a stronger estimate.

Example 02

500W load on 1,024Wh

The same battery calculates to about 1.6 hours. High-load conversion behavior and battery temperature can move the result.

Example 03

A 1,000W appliance

Runtime is under an hour for most models here. Continuous and starting output remain separate pass/fail checks.

Capacity evidence

Official regional source pages

These links support the listed capacity and model identity only. They do not prove current stock, delivered price, warranty handling or suitability for your load.