Language and regionEnglish · InternationalEN
Worked example · Ten-hour field day

Starlink Mini mobile internet for a long field day

A ten-hour Starlink Mini power budget with phone charging and task lighting, including battery-only and daily-solar checks.

3 device types20% extra energy marginWithout recharging
Quick answer

Battery target for 1 day

758Wh

Stated battery capacity, including a 20% extra energy margin on demand and 80% usable energy.

Adjust this example

Using the top of Starlink Mini’s official average range, the bundle consumes about 505Wh. With reserve and conversion allowance, its rated battery target is about 758Wh.

Energy per day
505 Wh
Power × hours × quantity
Power check
70 / 90 W
Simultaneous / peak — planning values
Solar target
200 W
4 peak sun hours · 75% yield

Solar is a separate estimate. The battery target is calculated without intermediate recharging.

Shortlist first

Stations to compare first

We check both battery size and whether the station can handle the load. Solar compatibility is still a separate check.

19 of 19 meet the target

First models that meet both the battery and power target, then the longest calculated coverage. No ranking on price or portability.

EcoFlow DELTA Pro 3

Photo: EU versionEcoFlow ↗

EcoFlow

DELTA Pro 3

4,096 Wh · 4,000 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
3,277 Wh
Coverage without extra margin
6.5 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
2,600 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
Anker SOLIX F3800
Anker SOLIX

F3800

3,840 Wh · 6,000 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
3,072 Wh
Coverage without extra margin
6.1 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
2,400 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
Anker SOLIX F3000
Anker SOLIX

F3000

3,072 Wh · 3,600 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
2,458 Wh
Coverage without extra margin
4.9 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
2,400 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
View all 19 models
Jackery Explorer 3000 v2

Photo: EU versionJackery ↗

Jackery

Explorer 3000 v2

3,072 Wh · 3,600 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
2,458 Wh
Coverage without extra margin
4.9 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
1,000 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
EcoFlow DELTA 2 Max

Photo: EU versionEcoFlow ↗

EcoFlow

DELTA 2 Max

2,048 Wh · 2,400 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
1,638 Wh
Coverage without extra margin
3.2 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
1,000 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
BLUETTI AC200L

Photo: EU versionBLUETTI ↗

BLUETTI

AC200L

2,048 Wh · 2,400 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
1,638 Wh
Coverage without extra margin
3.2 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
1,200 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
Jackery Explorer 2000 Plus

Photo: EU versionJackery ↗

Jackery

Explorer 2000 Plus

2,043 Wh · 3,000 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
1,634 Wh
Coverage without extra margin
3.2 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
1,400 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
Jackery Explorer 2000 v2

Photo: EU versionJackery ↗

Jackery

Explorer 2000 v2

2,042 Wh · 2,200 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
1,634 Wh
Coverage without extra margin
3.2 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
400 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
BLUETTI AC180

Photo: EU versionBLUETTI ↗

BLUETTI

AC180

1,152 Wh · 1,800 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
922 Wh
Coverage without extra margin
1.8 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
500 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
Jackery Explorer 1000 v2

Photo: EU versionJackery ↗

Jackery

Explorer 1000 v2

1,070 Wh · 1,500 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
856 Wh
Coverage without extra margin
1.7 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
400 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
Anker SOLIX C1000
Anker SOLIX

C1000

1,056 Wh · 1,800 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
845 Wh
Coverage without extra margin
1.7 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
600 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
EcoFlow DELTA 2

Photo: EU versionEcoFlow ↗

EcoFlow

DELTA 2

1,024 Wh · 1,800 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
819 Wh
Coverage without extra margin
1.6 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
500 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
EcoFlow DELTA 3 Plus

Photo: EU versionEcoFlow ↗

EcoFlow

DELTA 3 Plus

1,024 Wh · 1,800 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
819 Wh
Coverage without extra margin
1.6 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
1,000 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
DJI Power 1000

Photo: EU versionDJI ↗

DJI

Power 1000

1,024 Wh · 2,200 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
819 Wh
Coverage without extra margin
1.6 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
800 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
Anker SOLIX C1000 Gen 2
Anker SOLIX

C1000 Gen 2

1,024 Wh · 2,000 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
819 Wh
Coverage without extra margin
1.6 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
600 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
BLUETTI Elite 100 V2

Photo: EU versionBLUETTI ↗

BLUETTI

Elite 100 V2

1,024 Wh · 1,800 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
819 Wh
Coverage without extra margin
1.6 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
1,000 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
EcoFlow RIVER 3 Max Plus

Photo: EU versionEcoFlow ↗

EcoFlow

RIVER 3 Max Plus

858 Wh · 600 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
686 Wh
Coverage without extra margin
1.4 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
220 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
BLUETTI AC70

Photo: EU versionBLUETTI ↗

BLUETTI

AC70

768 Wh · 1,000 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
614 Wh
Coverage without extra margin
1.2 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
500 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
Anker SOLIX C800
Anker SOLIX

C800

768 Wh · 1,200 W continu

Meets the target

View this model
Why this outcome?
Usable battery · 80%
614 Wh
Coverage without extra margin
1.2 days
Battery target with extra margin
Met
Power target
Met
Solar input · watt limit
300 W · sufficient

Calculated solar lower bound: 168.3 W. The overview rounds this up to 50 W.

A watt limit does not prove a panel fits. Also check voltage, current, connectors and the regional version.

Check solar panel
What is included

The devices in this example

These are sensible starting values. Change the hours and exact devices in the planner to make the answer yours.

Adjust devices
  • Starlink Mini

    400 Wh per day
    Average consumption
    40 W
    Entered peak
    60 W
    Hours per day
    10 hours
    Quantity
    1
  • Phone charging

    30 Wh per day
    Average consumption
    15 W
    Entered peak
    20 W
    Hours per day
    2 hours
    Quantity
    1
  • LED task lights

    75 Wh per day
    Average consumption
    15 W
    Entered peak
    15 W
    Hours per day
    5 hours
    Quantity
    1
Total for one day505 Wh
Useful tip 1

The smaller setup in this library

Unlike a full laptop workday, this connectivity-only bundle can fit some current candidates for one conservative day.

Useful tip 2

Keep the cable path explicit

Starlink Mini supports specific DC and USB-C conditions. A physical plug alone does not prove a supported path.

Calculation detailsSee the assumptions behind this answer
  1. Starlink Mini is planned at 40W for ten hours
  2. One phone receives two hours at a 15W charging average
  3. Task lighting adds 15W for five hours
  4. The Starlink Mini peak remains a separate output check

How the battery target is formed

505 Wh per day × 1 day × 1.2 ÷ 0.8 ≈ 758 Wh

The daily consumption above is rounded for display. The calculation uses unrounded values. The factor is 1 + the extra energy margin, added to demand rather than kept as battery charge; the 80% usable-energy allowance is a separate factor.
SourcesSee manuals and supporting guides
Official Starlink Mini specification sheet↗Your Power Setup Starlink Mini sizing guide→