Solar checker

Your panels. The right connection.

Choose a panel and check its electrical limits before connecting it.

Browse solar panels ↗
Foldable solar panel on grass connected to a portable power device
01

Which panel?

200watts
Renogy 200W N-Type Bifacialrigid
Panel data & source Manufacturer profile

This panel can also collect light from the back. Our calculation leaves that possible extra output out to avoid an optimistic result.

Checked:

Review or edit the valuesAlready filled in

Take these values from the exact panel label or datasheet. Do not guess a missing temperature coefficient.

What do these terms mean? →
02

Your panel layout

Panels per stringIn series · increases voltage
1
Identical stringsSplit over inputs where modeled
1
1 × 11 identical panels in total
How are the strings connected?

Panels in a string are connected in series. The calculation distributes identical strings across the station’s modeled inputs; extra strings on one input are parallel. This is not a wiring diagram.

Only identical panels and equal string lengths are modeled. Fuses, cable gauge, grounding and local installation rules need a separate check.

Compare the inputs

Which station fits the calculation?

Sorted by modeled limits. Not a purchase recommendation or wiring approval.

Within modeled limitsBLUETTI

AC70

12–58 V · 10 A per input

Why this result?
Charging voltage
25 VLimit: 12–58 VWithin limit
Voltage in cold weather
32.3 VLimit: < 58 VWithin limit
Current per used input
8 ALimit: ≤ 10 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 12–58V input, 10A and 500W maximum.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60PM-M via included MC4 solar cable

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
Within modeled limitsBLUETTI

AC180

12–60 V · 10 A per input

Why this result?
Charging voltage
25 VLimit: 12–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 10 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 12–60V DC7909 input, 10A and 500W maximum. Panel Voc must remain below 60V.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → DC7909 via MC4 solar cable

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
Within modeled limitsEcoFlow

DELTA 2

11–60 V · 15 A per input

Why this result?
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 11–60V input, 15A and 500W maximum.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
All power stations 19
BLUETTI AC70Within modeled limits
Charging voltage
25 VLimit: 12–58 VWithin limit
Voltage in cold weather
32.3 VLimit: < 58 VWithin limit
Current per used input
8 ALimit: ≤ 10 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 12–58V input, 10A and 500W maximum.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60PM-M via included MC4 solar cable

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
BLUETTI AC180Within modeled limits
Charging voltage
25 VLimit: 12–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 10 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 12–60V DC7909 input, 10A and 500W maximum. Panel Voc must remain below 60V.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → DC7909 via MC4 solar cable

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA 2Within modeled limits
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 11–60V input, 15A and 500W maximum.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA 3 PlusWithin modeled limits
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

Two independent 11–60V inputs; each accepts 15A and 500W, for 1,000W total.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Anker SOLIX C1000Within modeled limits
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 10 AWithin limit
Power per used input
200 WLimit: ≤ 600 WWithin limit

The cited guide limits current to 10A from 11–32V and 12.5A from 32–60V, with 600W maximum.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Jackery Explorer 1000 v2Within modeled limits
Charging voltage
25 VLimit: 16–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 10.5 AWithin limit
Power per used input
200 WLimit: ≤ 200 WWithin limit

Two parallel DC8020 inputs; each supports 200W and 10.5A, for 400W total with matched panel groups.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Anker SOLIX C800Within modeled limits
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 10 AWithin limit
Power per used input
200 WLimit: ≤ 300 WWithin limit

One 11–60V input, 10A and 300W maximum. The exact included solar lead varies by bundle and market.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
BLUETTI Elite 100 V2Within modeled limits
Charging voltage
25 VLimit: 12–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 20 AWithin limit
Power per used input
200 WLimit: ≤ 1,000 WWithin limit

The manual treats the two MC4 pairs as parallel feeds into one 12–60V, 20A and 1,000W DC input. Use matched panel groups.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → BLUETTI solar cable with two MC4 pairs

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Jackery Explorer 2000 v2Within modeled limits
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 12 AWithin limit
Power per used input
200 WLimit: ≤ 200 WWithin limit

Two DC8020 inputs share a 400W ceiling. Jackery documents 11–16V at 8A and 16–60V at 12A per high-voltage input, with 21A combined maximum.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA 2 MaxWithin modeled limits
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

Two independent 11–60V inputs; each accepts 15A and 500W, for 1,000W total.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
BLUETTI AC200LWithin modeled limits
Charging voltage
25 VLimit: 12–145 VWithin limit
Voltage in cold weather
32.3 VLimit: < 145 VWithin limit
Current per used input
8 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 1,200 WWithin limit

One 12–145V input, 15A and 1,200W maximum. Keep the complete string open-circuit voltage inside the documented range.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → BLUETTI DC input via MC4 solar cable

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Jackery Explorer 2000 PlusWithin modeled limits
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 12 AWithin limit
Power per used input
200 WLimit: ≤ 700 WWithin limit

Two DC8020 inputs share a 1,400W ceiling. Jackery documents 11–17.5V at 8A and 17.5–60V at 12A per input, with 24A combined maximum.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Jackery Explorer 3000 v2Within modeled limits
Charging voltage
25 VLimit: 12–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 12 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

Two DC8020 inputs share a 1,000W ceiling. Jackery documents 12–16V at 8A and 16–60V at 12A per input, with 24A combined maximum.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Anker SOLIX C1000 Gen 2Needs a manual check
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 8.2 AWithin limit
Power per used input
200 WLimit: ≤ 600 WWithin limit

One XT60i input: 11–28V at 8.2A, then 29–60V at 14.5A, with 600W maximum.

Short-circuit current (Isc): 8.7 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow RIVER 3 Max PlusNeeds a manual check
Charging voltage
25 VLimit: 11–55 VWithin limit
Voltage in cold weather
32.3 VLimit: < 55 VWithin limit
Current per used input
8 ALimit: ≤ 8 AWithin limit
Power per used input
200 WLimit: ≤ 220 WWithin limit

One 11–55V input, 8A and 220W maximum on the RIVER 3 Plus base unit.

Short-circuit current (Isc): 8.7 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Anker SOLIX F3000Needs a manual check
Charging voltage
25 VLimit: 11–165 VWithin limit
Voltage in cold weather
32.3 VLimit: < 165 VWithin limit
Current per used input
8 ALimit: ≤ 17 AWithin limit
Power per used input
200 WLimit: ≤ 1,600 WWithin limit

This check models the 11–165V, 17A and 1,600W high-PV input. A separate low-PV input accepts 11–60V, 17A and 800W; together Anker lists 2,400W total.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Only the listed primary input is modeled. This station has another, different PV input that this result does not model.

Cable route — not yet verifiedSolar connectors → High-PV input

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Anker SOLIX F3800Needs a manual check
Charging voltage
25 VLimit: 11–60 VWithin limit
Voltage in cold weather
32.3 VLimit: < 60 VWithin limit
Current per used input
8 ALimit: ≤ 27 AWithin limit
Power per used input
200 WLimit: ≤ 1,200 WWithin limit

Two XT60 inputs accept up to 1,200W each. Current bands depend on firmware: newer firmware lists 10A at 11–15V and up to 27A at 15–60V; verify the installed firmware before designing an array.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → XT60

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA Pro 3Needs a manual check
Charging voltage
25 VLimit: 30–150 VOutside limit
Voltage in cold weather
32.3 VLimit: < 150 VWithin limit
Current per used input
8 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 1,600 WWithin limit

This check models the 30–150V, 15A and 1,600W high-PV input. A separate low-PV input accepts 11–60V, 20A and 1,000W; together EcoFlow lists 2,600W total.

Short-circuit current (Isc): 8.7 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Only the listed primary input is modeled. This station has another, different PV input that this result does not model.

Cable route — not yet verifiedSolar connectors → High-PV input

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
DJI Power 1000Outside a hard limit
Charging voltage
25 VLimit: 32–58.4 VOutside limit
Voltage in cold weather
32.3 VLimit: < 58.4 VWithin limit
Current per used input
8 ALimit: ≤ 8 AWithin limit
Power per used input
200 WLimit: ≤ 400 WWithin limit

Two SDC inputs; each is documented at 32–58.4V, 8A and 400W maximum. External MPPT modules are required.

Short-circuit current (Isc): 8.7 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedSolar connectors → DJI SDC solar module

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
Privacy
YOUR POWER SETUP

Cookies

May we use Google Analytics cookies to understand which pages are useful? Only with your permission. We do not send calculator entries. You can change your choice below at any time. Cookie policy · Privacy