Language and regionEnglish · InternationalEN

Solar checker

Your panels. The right connection.

Choose a panel and check its electrical limits before connecting it.

Browse solar panels ↗
Foldable solar panel on grass connected to a portable power device
01

Which panel?

200watts
Jackery SolarSaga 200Wportable
Panel data & source Manufacturer profile

These are the official values for the front of the panel. The included cable or adapter can differ by country, so check your box before connecting.

Checked:

Review or edit the valuesAlready filled in

Take these values from the exact panel label or datasheet. Do not guess a missing temperature coefficient.

What do these terms mean? →
02

Your panel layout

Panels per stringIn series · increases voltage
1
Identical stringsSplit over inputs where modeled
1
1 × 11 identical panels in total
How are the strings connected?

Panels in a string are connected in series. The calculation distributes identical strings across the station’s modeled inputs; extra strings on one input are parallel. This is not a wiring diagram.

Only identical panels and equal string lengths are modeled. Fuses, cable gauge, grounding and local installation rules need a separate check.

Compare the inputs

Which station fits the calculation?

Sorted by modeled limits. Not a purchase recommendation or wiring approval.

Within modeled limitsEcoFlow

DELTA 2

11–60 V · 15 A per input

Why this result?
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 11–60V input, 15A and 500W maximum.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
Within modeled limitsEcoFlow

DELTA 3 Plus

11–60 V · 15 A per input

Why this result?
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

Two independent 11–60V inputs; each accepts 15A and 500W, for 1,000W total.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
Within modeled limitsBLUETTI

Elite 100 V2

12–60 V · 20 A per input

Why this result?
Charging voltage
18 VLimit: 12–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 20 AWithin limit
Power per used input
200 WLimit: ≤ 1,000 WWithin limit

The manual treats the two MC4 pairs as parallel feeds into one 12–60V, 20A and 1,000W DC input. Use matched panel groups.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → BLUETTI solar cable with two MC4 pairs

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
All power stations 19
EcoFlow DELTA 2Within modeled limits
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 11–60V input, 15A and 500W maximum.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA 3 PlusWithin modeled limits
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

Two independent 11–60V inputs; each accepts 15A and 500W, for 1,000W total.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
BLUETTI Elite 100 V2Within modeled limits
Charging voltage
18 VLimit: 12–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 20 AWithin limit
Power per used input
200 WLimit: ≤ 1,000 WWithin limit

The manual treats the two MC4 pairs as parallel feeds into one 12–60V, 20A and 1,000W DC input. Use matched panel groups.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → BLUETTI solar cable with two MC4 pairs

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA 2 MaxWithin modeled limits
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

Two independent 11–60V inputs; each accepts 15A and 500W, for 1,000W total.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
BLUETTI AC200LWithin modeled limits
Charging voltage
18 VLimit: 12–145 VWithin limit
Voltage in cold weather
24.1 VLimit: < 145 VWithin limit
Current per used input
11.5 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 1,200 WWithin limit

One 12–145V input, 15A and 1,200W maximum. Keep the complete string open-circuit voltage inside the documented range.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → BLUETTI DC input via MC4 solar cable

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Jackery Explorer 2000 v2Needs a manual check
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 12 AWithin limit
Power per used input
200 WLimit: ≤ 200 WWithin limit

Two DC8020 inputs share a 400W ceiling. Jackery documents 11–16V at 8A and 16–60V at 12A per high-voltage input, with 21A combined maximum.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Jackery Explorer 2000 PlusNeeds a manual check
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 12 AWithin limit
Power per used input
200 WLimit: ≤ 700 WWithin limit

Two DC8020 inputs share a 1,400W ceiling. Jackery documents 11–17.5V at 8A and 17.5–60V at 12A per input, with 24A combined maximum.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Anker SOLIX F3000Needs a manual check
Charging voltage
18 VLimit: 11–165 VWithin limit
Voltage in cold weather
24.1 VLimit: < 165 VWithin limit
Current per used input
11.5 ALimit: ≤ 17 AWithin limit
Power per used input
200 WLimit: ≤ 1,600 WWithin limit

This check models the 11–165V, 17A and 1,600W high-PV input. A separate low-PV input accepts 11–60V, 17A and 800W; together Anker lists 2,400W total.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Only the listed primary input is modeled. This station has another, different PV input that this result does not model.

Cable route — not yet verifiedJackery solar output lead → High-PV input

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Anker SOLIX F3800Needs a manual check
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 27 AWithin limit
Power per used input
200 WLimit: ≤ 1,200 WWithin limit

Two XT60 inputs accept up to 1,200W each. Current bands depend on firmware: newer firmware lists 10A at 11–15V and up to 27A at 15–60V; verify the installed firmware before designing an array.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Jackery Explorer 3000 v2Needs a manual check
Charging voltage
18 VLimit: 12–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 12 AWithin limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

Two DC8020 inputs share a 1,000W ceiling. Jackery documents 12–16V at 8A and 16–60V at 12A per input, with 24A combined maximum.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA Pro 3Needs a manual check
Charging voltage
18 VLimit: 30–150 VOutside limit
Voltage in cold weather
24.1 VLimit: < 150 VWithin limit
Current per used input
11.5 ALimit: ≤ 15 AWithin limit
Power per used input
200 WLimit: ≤ 1,600 WWithin limit

This check models the 30–150V, 15A and 1,600W high-PV input. A separate low-PV input accepts 11–60V, 20A and 1,000W; together EcoFlow lists 2,600W total.

Short-circuit current (Isc): 12.5 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Only the listed primary input is modeled. This station has another, different PV input that this result does not model.

Cable route — not yet verifiedJackery solar output lead → High-PV input

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 200 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
BLUETTI AC70Outside a hard limit
Charging voltage
18 VLimit: 12–58 VWithin limit
Voltage in cold weather
24.1 VLimit: < 58 VWithin limit
Current per used input
11.5 ALimit: ≤ 10 AOutside limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 12–58V input, 10A and 500W maximum.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60PM-M via included MC4 solar cable

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
BLUETTI AC180Outside a hard limit
Charging voltage
18 VLimit: 12–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 10 AOutside limit
Power per used input
200 WLimit: ≤ 500 WWithin limit

One 12–60V DC7909 input, 10A and 500W maximum. Panel Voc must remain below 60V.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → DC7909 via MC4 solar cable

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
DJI Power 1000Outside a hard limit
Charging voltage
18 VLimit: 32–58.4 VOutside limit
Voltage in cold weather
24.1 VLimit: < 58.4 VWithin limit
Current per used input
11.5 ALimit: ≤ 8 AOutside limit
Power per used input
200 WLimit: ≤ 400 WWithin limit

Two SDC inputs; each is documented at 32–58.4V, 8A and 400W maximum. External MPPT modules are required.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → DJI SDC solar module

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
Anker SOLIX C1000Outside a hard limit
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 10 AOutside limit
Power per used input
200 WLimit: ≤ 600 WWithin limit

The cited guide limits current to 10A from 11–32V and 12.5A from 32–60V, with 600W maximum.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
Anker SOLIX C1000 Gen 2Outside a hard limit
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 8.2 AOutside limit
Power per used input
200 WLimit: ≤ 600 WWithin limit

One XT60i input: 11–28V at 8.2A, then 29–60V at 14.5A, with 600W maximum.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
Jackery Explorer 1000 v2Outside a hard limit
Charging voltage
18 VLimit: 16–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 10.5 AOutside limit
Power per used input
200 WLimit: ≤ 200 WWithin limit

Two parallel DC8020 inputs; each supports 200W and 10.5A, for 400W total with matched panel groups.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
Anker SOLIX C800Outside a hard limit
Charging voltage
18 VLimit: 11–60 VWithin limit
Voltage in cold weather
24.1 VLimit: < 60 VWithin limit
Current per used input
11.5 ALimit: ≤ 10 AOutside limit
Power per used input
200 WLimit: ≤ 300 WWithin limit

One 11–60V input, 10A and 300W maximum. The exact included solar lead varies by bundle and market.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
EcoFlow RIVER 3 Max PlusOutside a hard limit
Charging voltage
18 VLimit: 11–55 VWithin limit
Voltage in cold weather
24.1 VLimit: < 55 VWithin limit
Current per used input
11.5 ALimit: ≤ 8 AOutside limit
Power per used input
200 WLimit: ≤ 220 WWithin limit

One 11–55V input, 8A and 220W maximum on the RIVER 3 Plus base unit.

Short-circuit current (Isc): 12.5 A per used input. Above the modeled current limit: ask the manufacturer to confirm Isc acceptance.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedJackery solar output lead → XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Product profile →
Privacy