Language and regionEnglish · InternationalEN
Four source-linked panel classes

Same watts.
Different electrical fit.

Compare the figures that change an array—not just the number printed largest on the box. A higher voltage or current is not automatically better; it must fit the station’s documented input.

Side-by-side tool

Choose two exact panels.

No synthetic winner: voltage headroom, current limits, portability and cable paths solve different setup problems.

SpecificationOne panel · manufacturer values
Renogy

200W N-Type Bifacial

Fixed vehicle, shed or cabin arrays that suit its higher operating voltage.

EcoFlow

220W Bifacial

Foldable, higher-output charging for compatible portable power stations.

Rated power200W220W
Vmp · working voltage25V18.4V
Voc · open-circuit voltage29.6V21.8V
Estimated Voc at −10°C32.3V*24.3V*
Imp · working current8A12A
Isc · short-circuit current8.7A13A
ConnectorSolar connectorsMC4
FormatRigid · model RSP200DCTPortable · front-side STC values
Open-circuit voltage gap7.8V

This gap multiplies with every panel placed in series and grows again in cold conditions.

Working-current gap4.0A

This gap matters most when strings are placed in parallel or an input has a tight current limit.

*Cold Voc is a planning estimate at −10°C using each published temperature coefficient. It is not a wiring approval. Verify the exact label, lowest local temperature, station manual, connector, polarity, fuse and cable rating.