Solar checker

Your panels. The right connection.

Choose a panel and check its electrical limits before connecting it.

Browse solar panels ↗
Foldable solar panel on grass connected to a portable power device
01

Which panel?

100watts
EcoFlow 100W Flexibleflexible
Panel data & source Manufacturer profile

We filled in the electrical limits from EcoFlow’s official manual for this exact 100W flexible model.

Checked:

Review or edit the valuesAlready filled in

Take these values from the exact panel label or datasheet. Do not guess a missing temperature coefficient.

What do these terms mean? →
02

Your panel layout

Panels per stringIn series · increases voltage
1
Identical stringsSplit over inputs where modeled
1
1 × 11 identical panels in total
How are the strings connected?

Panels in a string are connected in series. The calculation distributes identical strings across the station’s modeled inputs; extra strings on one input are parallel. This is not a wiring diagram.

Only identical panels and equal string lengths are modeled. Fuses, cable gauge, grounding and local installation rules need a separate check.

Compare the inputs

Which station fits the calculation?

Sorted by modeled limits. Not a purchase recommendation or wiring approval.

Within modeled limitsAnker SOLIX

C1000

11–60 V · 12.5 A per input

Why this result?
Charging voltage
17.1 VLimit: 11–60 VWithin limit
Voltage in cold weather
22.6 VLimit: < 60 VWithin limit
Current per used input
5.9 ALimit: ≤ 10 AWithin limit
Power per used input
100 WLimit: ≤ 600 WWithin limit

The cited guide limits current to 10A from 11–32V and 12.5A from 32–60V, with 600W maximum.

Short-circuit current (Isc): 6.3 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedMC4 → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 100 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
Within modeled limitsEcoFlow

DELTA 2 Max

11–60 V · 15 A per input

Why this result?
Charging voltage
17.1 VLimit: 11–60 VWithin limit
Voltage in cold weather
22.6 VLimit: < 60 VWithin limit
Current per used input
5.9 ALimit: ≤ 15 AWithin limit
Power per used input
100 WLimit: ≤ 500 WWithin limit

Two independent 11–60V inputs; each accepts 15A and 500W, for 1,000W total.

Short-circuit current (Isc): 6.3 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedMC4 → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 100 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
Within modeled limitsJackery

Explorer 3000 v2

12–60 V · 12 A per input

Why this result?
Charging voltage
17.1 VLimit: 12–60 VWithin limit
Voltage in cold weather
22.6 VLimit: < 60 VWithin limit
Current per used input
5.9 ALimit: ≤ 12 AWithin limit
Power per used input
100 WLimit: ≤ 500 WWithin limit

Two DC8020 inputs share a 1,000W ceiling. Jackery documents 12–16V at 8A and 16–60V at 12A per input, with 24A combined maximum.

Short-circuit current (Isc): 6.3 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedMC4 → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 100 W. A limit, not a forecast of solar yield or permission to connect.

Product profile ↗
All power stations 4
Anker SOLIX C1000Within modeled limits
Charging voltage
17.1 VLimit: 11–60 VWithin limit
Voltage in cold weather
22.6 VLimit: < 60 VWithin limit
Current per used input
5.9 ALimit: ≤ 10 AWithin limit
Power per used input
100 WLimit: ≤ 600 WWithin limit

The cited guide limits current to 10A from 11–32V and 12.5A from 32–60V, with 600W maximum.

Short-circuit current (Isc): 6.3 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedMC4 → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 100 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA 2 MaxWithin modeled limits
Charging voltage
17.1 VLimit: 11–60 VWithin limit
Voltage in cold weather
22.6 VLimit: < 60 VWithin limit
Current per used input
5.9 ALimit: ≤ 15 AWithin limit
Power per used input
100 WLimit: ≤ 500 WWithin limit

Two independent 11–60V inputs; each accepts 15A and 500W, for 1,000W total.

Short-circuit current (Isc): 6.3 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedMC4 → XT60 / XT60i

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 100 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
Jackery Explorer 3000 v2Within modeled limits
Charging voltage
17.1 VLimit: 12–60 VWithin limit
Voltage in cold weather
22.6 VLimit: < 60 VWithin limit
Current per used input
5.9 ALimit: ≤ 12 AWithin limit
Power per used input
100 WLimit: ≤ 500 WWithin limit

Two DC8020 inputs share a 1,000W ceiling. Jackery documents 12–16V at 8A and 16–60V at 12A per input, with 24A combined maximum.

Short-circuit current (Isc): 6.3 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Cable route — not yet verifiedMC4 → DC8020

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 100 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →
EcoFlow DELTA Pro 3Needs a manual check
Charging voltage
17.1 VLimit: 30–150 VOutside limit
Voltage in cold weather
22.6 VLimit: < 150 VWithin limit
Current per used input
5.9 ALimit: ≤ 15 AWithin limit
Power per used input
100 WLimit: ≤ 1,600 WWithin limit

This check models the 30–150V, 15A and 1,600W high-PV input. A separate low-PV input accepts 11–60V, 20A and 1,000W; together EcoFlow lists 2,600W total.

Short-circuit current (Isc): 6.3 A per used input. Still verify protection and wiring requirements.

Calculation assumes: 1 identical strings across 1 used input(s).

Only the listed primary input is modeled. This station has another, different PV input that this result does not model.

Cable route — not yet verifiedMC4 → High-PV input

Check the exact adapter, polarity, fuses and cable ratings in both manuals.

Modeled power ceiling: 100 W. A limit, not a forecast of solar yield or permission to connect.

Product profile →