Language and regionEnglish · AustraliaAU
Four source-linked panel classes

Same watts.
Different electrical fit.

Compare the figures that change an array—not just the number printed largest on the box. A higher voltage or current is not automatically better; it must fit the station’s documented input.

Side-by-side tool

Two exact panels.

The selected pair comes from the URL. Use a profile or the panel library to choose another source-linked model.

SpecificationOne panel · manufacturer values
Jackery

SolarSaga 200W

Portable charging where a foldable panel and manufacturer cable path are priorities.

EcoFlow

220W Bifacial

Foldable, higher-output charging for compatible portable power stations.

Rated power200W220W
Vmp · working voltage18V18.4V
Voc · open-circuit voltage22V21.8V
Estimated Voc at −10°C24.1V*24.3V*
Imp · working current11.5A12A
Isc · short-circuit current12.5A13A
ConnectorJackery solar output leadMC4
FormatPortable · front-side STC valuesPortable · front-side STC values
Open-circuit voltage gap0.2V

This gap multiplies with every panel placed in series and grows again in cold conditions.

Working-current gap0.5A

This gap matters most when strings are placed in parallel or an input has a tight current limit.

*Cold Voc is a planning estimate at −10°C using each published temperature coefficient. It is not a wiring approval. Verify the exact label, lowest local temperature, station manual, connector, polarity, fuse and cable rating.

Privacy